Generator Reviews

Diesel Generators 7.5 KVA to 40 KVA Specification

Contain in this article are the general information one may need to know about Diesel Generator 7.5 KVA to 40 KVA. These includes technical, Engine and alternator specifications of Diesel Generator 7.5 KVA to 40 KVA

Technical Specifications for Diesel Generators 7.5 KVA to 40 KVA

Model FGN-7.5 FELS -15 FELS – 20 FELS-30 FELS-40
PRIME POWER RATING 7.5KVA/6KW 15KVA/12KW 20KVA/16KW 30KVA/24KW 40KVA/32KW
CURRENT SINGLE PHASE 26 65 87 130 174
CURRENT THREE PHASE   21 28 42 56
Power Factor 0.8(lag) 0.8(lag) 0.8(lag) 0.8(lag) 0.8(lag)

Engine Specifications For Diesel Generator 7.5 KVA to 40 KVA

Make GREAVES ESCORTS ESCORTS ESCORTS ESCORTS
ASPIRATION NATURAL NATURAL NATURAL NATURAL TURBO CHARGED
RPM 3000 1500 1500 1500 1500
BHP 11 22 28 43 58
No. of cylinders 1 2 3 3 4
Bore x Stroke (mm) 92 X92 95X110 91X110 105X120 91X110
Compression ratio 18:01 17.5:1 17.5:1 17.5:1 17.5:1
Displacement (cc) 611 1560 2150 3120 2860
Fuel HSD HSD HSD HSD HSD
FUEL CONSUMPTION LPH @ 100 % LOAD 2.3 3.78 4.9 7.7 8.5
FUEL CONSUMPTION LPH @ 75% LOAD 1.9 2.85 3.7 5.5 6.5
Governor A-2 MECHANICAL A-1 MECHANICAL A-1 MECHANICAL A-1 MECHANICAL A-1 MECHANICAL
Starting system 12 V Electrical 12 V Electrical 12 V Electrical 12 V Electrical 12 V Electrical
Lube oil specification 15W40CF4 15W40CF4 15W40CF4 15W40CF4 15W40CF4
LUBE OIL SUMP CAPACITY (LTR) 1.75 6 6 6 6
LUBE OIL CONSUMPTION MAX (% OF FUEL) 0.2 0.1 0.1 0.1 0.1
TOTAL COOLANT CAPACITY 5.5 10.9 10.9 12.4 12.4
EXHAUST PIPE SIZING 50 50 50 50 50
Battery capacity 88 AH 12V 100 AH 12V 100 AH 12V 100 AH 12V 100 AH 12V

Alternator Specifications For Diesel Generator 7.5 KVA to 40 KVA

Make NSM Leroy-Somer Leroy-Somer Leroy-Somer Leroy-Somer
VOLTAGE SINGLE PHASE 230V 230V 230V 230V 230V
VVOLTAGE THREE PHASE   415V 415V 415V 415V
RPM/Frequency 3000 RPM/50HZ 1500RPM /50HZ 1500RPM /50HZ 1500RPM /50HZ 1500RPM /50HZ
Voltage regulation (max) +/- 1% +/- 1% +/- 1% +/- 1% +/- 1%
Class of insulation H H H H H

Note:

  • Fuel Consumption based on recommended diesel fuel.
  • Fuel Consumption values are with 0 to 5% tolerence.
  • Oil Consumption based on recommended oils.

See: About 7.5 KVA Diesel Generators